Vibration analysis: how imbalance and bearing damage give themselves away

By Tobias Schott  · 5-minute read · Updated November 2026

Every rotating machine vibrates – vibration analysis shows whether it vibrates as it always has, or whether imbalance, misalignment or bearing damage is developing.

You come across vibration analysis in the measurement report after a walk-round, in the acceptance record after a machine relocation, or as a traffic light on the screen of a permanently installed monitoring system. It shows values in millimetres per second, sometimes a chart with peaks. What does that mean for your motor, your fan, your pump?

This article explains what is measured, how a curve turns into a cause and why the trend matters more than the limit value. How to maintain drives, gearboxes and pumps is covered in the guide Maintaining drives, gearboxes and pumps.

What is vibration analysis?

Vibration analysis is the measurement of a machine’s mechanical movement at defined measuring points, usually on the bearing housings, to assess its condition. A sensor, often an accelerometer, is attached to the housing with a magnet or a screw. It converts the movement into an electrical signal, and the instrument calculates overall values and spectra from it.

Vibration occurs because the forces in a machine are never perfectly balanced. A rotor is never perfectly balanced, two shafts are never perfectly aligned, a bearing never rolls perfectly. As long as the pattern stays stable, this is normal. If it changes, something in the machine has changed. In German the method is called “Schwingungsmessung”; in English it is known as vibration analysis or vibration monitoring.

Key facts

Overall value, spectrum, envelope: what is measured

Vibration analysis has three levels: the overall value tells you whether something is changing, the spectrum tells you what it is, and the envelope finds bearing damage earliest.

Technical drawing: three levels of vibration analysis – a handheld device shows a single overall value, a spectrum shows peaks at one, two and three times running speed, a time signal with short impacts is filtered into the envelope
Overall value for the round, spectrum for the cause, envelope for early bearing damage. Graphic: Omega Mounting

Overall value. The handheld meter measures vibration velocity over a wide frequency range, typically 10 to 1,000 hertz, and shows a single number. ISO 20816, the successor to ISO 10816, classifies such values by machine group and mounting into zones from “new” to “damage possible”. On a walk-round, the overall value is enough to see a change.

Spectrum. Frequency analysis breaks the signal down into its components. Each peak in the spectrum belongs to a frequency – and many faults have their own. The reference point is the shaft’s rotational frequency: the speed in revolutions per minute divided by 60.

Envelope. Incipient damage on the raceway of a rolling bearing produces tiny, fast impacts. In the overall value they are lost. Envelope analysis filters out these impacts and makes bearing damage visible long before the bearing runs warm or becomes audible.

Imbalance, misalignment, bearing damage: which vibration belongs to which fault

Explainer graphic: vibration analysis – typical features of imbalance, misalignment, looseness, bearing damage and gear mesh in the frequency spectrum
Every fault has its frequency: only the spectrum separates imbalance from misalignment and bearing damage. Graphic: Omega Mounting

The cause gives itself away through the frequency and direction of the vibration – which is why a spectrum says more than a single value.

Schematic drawing: three vibration spectra – with imbalance the running speed peak stands out, with misalignment one and two times running speed are high, with mechanical looseness many multiples appear
Imbalance, misalignment, looseness: which multiples of running speed stand out reveals the cause. Graphic: Omega Mounting
FaultTypical featureDirectionTypical action
ImbalanceHigh peak at 1× rotational frequencyMainly radialClean the rotor, remove build-up, balance
MisalignmentPeaks at 1× and 2× rotational frequencyHigh axial componentAlign the shafts, check the coupling
Mechanical loosenessMany multiples of rotational frequency, unsteady signalOften vertical at the footCheck foot bolts, foundation, bearing seat
Rolling bearing damageSpecific bearing frequencies, early in the envelope, later broadband noiseRadial at the affected bearingCheck lubrication, replace the bearing, find the cause
Gear teethPeak at gear mesh frequency, i.e. number of teeth × rotational frequencyRadial and axial at the gearboxCheck oil condition, inspect the gear teeth
BeltsFrequencies below rotational frequency, fluctuatingRadial in the direction of the beltCheck tension, alignment and belt condition

The table shows typical patterns. In practice several causes overlap, and a measurement at a single point is rarely enough. The diagnosis is made by someone who knows both the spectrum and the machine.

Technical drawing: motor with shaft and plummer block, sensors on the bearing housing measure radial vertical from above, radial horizontal across the shaft and axial in the shaft direction
Radial vertical, radial horizontal, axial: measure close to the bearing and always at the same point. Graphic: Omega Mounting

Why the trend counts more than the limit value

A vibration value only means something in comparison – with the last measurement, with the neighbouring machine and with the condition after the last repair.

Schematic diagram: vibration velocity over several measurements with zones – the value rises in the lower range, after a bearing change it drops to a new baseline and after later work jumps into the next zone
The rise is the finding, even in the green range – and a jump after work usually points to the work itself. Graphic: Omega Mounting

Every machine has its own normal condition. It depends on design, foundation, speed and load. That is why any monitoring needs a baseline: the measurement after installation, relocation or bearing replacement, recorded with measuring point and operating condition.

If the value rises from one round to the next, that is a finding – even if it is still in the green zone. If it jumps after a job, the job itself is usually the cause: misalignment after reinstallation, a foot bolt not tightened, a soft foot.

What we pay attention to

We measure with the handheld meter at the bearing positions and carry out repairs based on measurement reports – bearings, alignment, foundation.

The removed fan impeller – ready for bearing replacement and overhaul
Fan impellers are classic candidates for vibration analysis: imbalance and bearing damage show up long before the bearing fails.

Where we use it

On fans, motors and generator sets, vibration is the earliest sign of bearing damage. Take the fan bearing replacement in a paint shop near Offenbach – the fans ran practically non-stop; a worn bearing would have risked vibration, consequential damage to motor and impeller, and an unplanned shutdown. We removed the unit of motor and an impeller of around 1.40 metres, replaced the bearings and overhauled them. Our generator maintenance on a standby power system likewise included reconnecting the generator to the engine and aligning it during reinstallation. Both are part of our Maintenance and servicing.

More technology explained

Technology explained

the method that shows the same faults as heat.

Technology explained

how the misalignment shown in the spectrum is corrected.

Guide

the guide for when the looseness comes from the foundation.

Do you have questions about how this works on your site?

Questions about how this works in your plant – for example, what the red traffic light in your measurement report means? We check bearings, alignment and foundation and carry out the repair. Request a callback – we will get back to you.

Free, no-obligation callback

Tobias Schott, managing director of Omega Mounting GmbH, on a construction site in front of scaffolding

About the author

Tobias Schott

Managing director of Omega Mounting GmbH, Rodgau · more than 20 years of hands-on experience in installation and maintenance

A trained mechatronics technician, working in maintenance, servicing and industrial installation since 2004 – first alongside his father, and with Omega Mounting since 2012: from overhead conveyors in Frankfurt to the crane system in a new-build hall. He plans and leads lifting operations as an appointed person (AP) in data centers and on industrial sites in the Rhine-Main region, trains and examines operators of cranes, mobile elevating work platforms and telehandlers, and is a qualified occupational safety specialist. On jobs abroad he is known as the “German Troubleshooter” – the person you call when a site gets stuck. He learned what quality means from his father, not from a manual: Made in Germany as a standard for his own work, not a label. That is why quality comes first at Omega Mounting – ahead of speed and price. The Technology explained articles cover the equipment and techniques his team uses every day: what counts on site is in them – what only appears in the brochure is not.